Metgard RP 222

Corrosion Inhibitor

Metgard RP-222 is a water soluble, amine carboxylate based corrosion inhibitor that dries to a light dry film that prevents the atmosphere from contacting the parts. A small amount of surfactant contained in the product allows for superior wetting of the corrosion inhibitor across the part. Metgard RP-222 is safe on all metals but is primarily designed for use on steel. Metgard RP-222 is also bioresistant to a majority of the organisms that attack organic based fluids. When used in conjunction with certain packaging such as VCI bags, Metgard RP-222 has the potential to provide many months worth of corrosion protection.

Use Procedure

Concentration:
2%-10% (Based on length of time needed for protection)
Temperature:
Ambient to 125°F
Method (process):
Spray, Dip
Cycle Times:
Min. 20 seconds

Product Benefits

  • Film formation is non-oily/non-tacky
  • No white powdery residue left behind at any concentration
  • Rejects oils
  • Biodegradable

Product Safety Information

Do Not Ingest. Product may be harmful if swallowed. Cleaner RP-10 is an alkaline product and the concentrate may irritate skin and eyes. Gloves and splash goggles should be worn when handling product. For full safety and first aid information consult MSDS on this product prior to use.